Water activity and moisture content meter
AQUALAB 3
Fast, predictive water activity and total moisture measurements that enable real-time control and better decisions across production environments.

Built for production, QA, and R&D teams
AQUALAB 3 uses chilled mirror dew point sensing and predictive AI to measure water activity and moisture content, helping food, pharmaceutical, and process manufacturers control moisture faster from formulation through finished product.
0.005aw
Water activity accuracy
≤5min
Typical read time





Predict, adjust, control
AQUALAB 3 delivers fast, accurate water activity measurements alongside total moisture content, enabling manufacturers to predict outcomes, adjust processes sooner, and maintain tighter control across diverse sample types.
One-minute insights
Predictive modeling delivers actionable water activity and moisture content data in as little as 60 seconds, reducing wait times compared to traditional methods—even for coated, high-fat, or complex products.
Trusted accuracy
Chilled mirror dew point technology delivers ±0.005 aw accuracy and up to 10× better moisture accuracy than the average moisture balance, supporting tighter specifications without increasing safety margins.
Proactive moisture control
Early indicators allow operators to adjust belt speed, temperature, or water content before problems occur, helping reduce failed batches, rework, and costly production interruptions.

Built for the line
AQUALAB instruments perform reliably in harsh production environments, delivering consistent, lab-quality measurements without requiring controlled laboratory conditions.
Compliance simplified
Secure data syncing, user management, and device connectivity help teams meet regulatory requirements and satisfy audits with minimal operational overhead.

Stackable by design
AQUALAB 3 features a compact, fully stackable design that saves valuable bench and line space, making it easy to deploy multiple instruments in crowded production and process control environments.

Ready out of the box
Each AQUALAB 3 ships with a calibrated sensor block, SKALA software, required accessories, and optional iPad—so teams can install quickly and begin generating reliable measurements immediately.
Shop accessories

Water activity standards
Certified salt standards for verifying water activity accuracy and repeatability across instruments, users, and locations. Each box contains 50 tubes.

Disposable sample cups
Single-use sample cups designed to prevent cross-contamination and ensure consistent, accurate water activity and moisture measurements.

Single-use cleaning swabs
Disposable swabs designed for quick chamber cleaning and contamination control between water activity or moisture measurements.
FAQs
What is Prop 65?
In 1986, California voters approved an initiative to help them make informed decisions about the products they buy. That initiative became known as Proposition 65. Proposition 65 requires the state of California to publish a list of chemicals known to cause cancer/ reproductive harm. You can learn more about Prop 65 here.
Why do AQUALAB products have a Prop 65 warning?
AQUALAB is required by California law to post a warning on any product that might be sold in California if it contains or might contain one of the more than 900 chemicals known to the state of California to cause cancer and/or reproductive harm. Because consumers learn about our products from our website, we are required to post these warnings on the product web pages as well. California residents are used to seeing these notifications on many products, including household items, electrical wires, electronics, jewelry, dishes, flashlights, cosmetics, skincare products, and much more. People who live outside the state of California may be surprised and alarmed by these notifications. It is important to know that nearly all electronic products require the notification label even though the chemicals involved may only be potentially harmful when eaten in large quantities.
Are AQUALAB products safe?
A Prop 65 warning does not necessarily mean a product is in violation of any product safety standards or requirements. Because AQUALAB sources manufacturing materials from other suppliers, we provide the warning in order to acknowledge that AQUALAB products may contain one or more of the chemicals listed. However, it’s likely that those chemicals are in such small
How can I minimize moisture migration in hygroscopic products during sampling?
The best approach is to put the water activity instrument and the sample into controlled humidity conditions. Use a glove box, or get the sample inside the chamber as quickly as possible to prevent water uptake from the environment. With an instrument that maintains the seal in the chamber, it’s possible to perform consecutive readings. But if the instrument requires pulling out the sample to take a new reading, the water activity will continually change as the sample takes up more and more moisture.
Is the whole tablet measurement of value?
It depends if the tablet is non-coated or coated. If the coating material can absorb water, there is a critical water activity where the coating material will begin to break down. Thus, if monitoring that aspect of the product, then reading the water activity of a whole tablet would be important.
Would you recommend breaking up a tablet with a mortar and pestle?
A mortar and pestle is a valuable tool for sample preparation because it breaks things apart without being too excessive. You can achieve the same effect with a coffee grinder or food processor, but use only a couple of quick pulses. Process just enough to break the sample apart without grinding it.
Downloads and documents
Technical specifications
Measurement specifications
Water Activity
Range:
0.0300 to 1.0000 aw
Resolution:
0.0001 aw
Accuracy:
±0.005 aw (dew point), ±0.015 aw (capacitance)
Repeatability:
0.002 aw (dew point), 0.010 aw (capacitance)
Sensor Type:
Chilled mirror dew point and capacitive hygrometer
Moisture Content
Accuracy:
0 – 1 % to moisture content reference
Repeatability:
0.02%
Operating Temperature
Controlled at constant
25 °C
Resolution:
0.10 °C
Accuracy:
±0.1 °C
Read Time
Minimum:
60 s
Typical:
~5 min
Physical specifications
Case Dimensions
Length:
23.4 cm (9.2 in)
Width:
23.4 cm (9.2 in)
Height:
12.1 cm (5.0 in)
Data Communications
Minimum:
60 s
Maximum:
200 s (estimated)
Case Material
Polycarbonate-ABS (PC-ABS)
Universal Power
110.0000 – 240.0000 V AC
Display
iPad
Sample Cup Capacity
7.5 mL (0.25 fl oz), partially full, recommended 15 mL (0.51 fl oz), full
Operating Temperature
Controlled at Constant:
25.00 °C
Accuracy:
0.10 °C
Resolution:
0.10 °C
Minimum:
15.00 °C
Maximum:
35.00 °C
Operating Environment
0.0 - 90.0 % noncondensing
Weight
5.0 kg (11 lb)
Data Communications
USB A to USB B 9,600 baud